Exterior Walls Insulation Continuous Insulation Wood Frame Construction Insulation Steel Stud

ROCKWOOL Comfortboard® 110

Comfortboard® 110 is a rigid, high-density, noncombustible, stone wool insulation board designed for use as an exterior continuous insulation in commercial and residential applications.

Comfortboard 110 is engineered for use with screw through insulation cladding support systems where a high compressive strength is required.

Back
Back

Specification & sizes

Compliance ASTM C612 - CAN/ULC S702
ASTM C612 Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant
CAN/ULC S702 Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant
Density ASTM C303
ASTM C303

Actual Density - 11 lb/ft³ (176 kg/m³)

Dimensions

1” to 5”: 24"x48" (610 mm x 1219 mm) 

1” to 3”: 48"x72" (1219 mm x 1829 mm)

 

Thickness

1" (25.4 mm)

1.25" (32 mm)

1.5” (38.1 mm)

2" (50.8 mm)

2.5" (63.5 mm)

3" (76.2 mm)

4” (101.6 mm)

5” (127 mm)

Reaction to fire ASTM E84 (UL 723) - CAN/ULC S102 - CAN/ULC S114
ASTM E84 (UL 723) Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102 Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114 Determination of Non-Combustibility of Building Materials - Non-Combustible
Thermal resistance ASTM C518 (C177)
ASTM C518 (C177) R-value / inch @ 75ºF - 4.0 hr.ft2.F/Btu
ASTM C518 (C177) RSI value / 25.4 mm @ 24ºC - 0.70 m2K/W
Acoustical Performance ASTM C423
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC
1" 0.13 0.49 0.85 0.89 0.89 0.97  0.8
2" 0.5 0.71 0.85 0.9 0.96 1.01 0.85
Reaction to moisture ASTM C1104 - ASTM E96 - ASTM C209 - ASTM C1338
ASTM C1104 Moisture Sorption - 0.28%
ASTM E96 Water Vapor Transmission, Desiccant Method - 2160 ng/Pa.s.m2 (35 perm)
ASTM C209 Water Absorption - 1.2%
ASTM C1338 Determination of Fungi Resistance - Passed
Compressive strength ASTC C165
ASTC C165 584 psf (28 kPa) @ 10% compression
ASTC C165 1566 psf (75 kPa) @ 25% compression
Corrosion Resistance ASTM C795 - ASTM C665
ASTM C795 Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665 Corrosion of Steel - Passed
ASTM C665 Corrosion to Aluminum - Passed
Back
ASTM C612 Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant
CAN/ULC S702 Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant
Back
ASTM C303

Actual Density - 11 lb/ft³ (176 kg/m³)

Back

1” to 5”: 24"x48" (610 mm x 1219 mm) 

1” to 3”: 48"x72" (1219 mm x 1829 mm)

 

Back

1" (25.4 mm)

1.25" (32 mm)

1.5” (38.1 mm)

2" (50.8 mm)

2.5" (63.5 mm)

3" (76.2 mm)

4” (101.6 mm)

5” (127 mm)

Back
ASTM E84 (UL 723) Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102 Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114 Determination of Non-Combustibility of Building Materials - Non-Combustible
Back
ASTM C518 (C177) R-value / inch @ 75ºF - 4.0 hr.ft2.F/Btu
ASTM C518 (C177) RSI value / 25.4 mm @ 24ºC - 0.70 m2K/W
Back
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC
1" 0.13 0.49 0.85 0.89 0.89 0.97  0.8
2" 0.5 0.71 0.85 0.9 0.96 1.01 0.85
Back
ASTM C1104 Moisture Sorption - 0.28%
ASTM E96 Water Vapor Transmission, Desiccant Method - 2160 ng/Pa.s.m2 (35 perm)
ASTM C209 Water Absorption - 1.2%
ASTM C1338 Determination of Fungi Resistance - Passed
Back
ASTC C165 584 psf (28 kPa) @ 10% compression
ASTC C165 1566 psf (75 kPa) @ 25% compression
Back
ASTM C795 Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665 Corrosion of Steel - Passed
ASTM C665 Corrosion to Aluminum - Passed
Item number Product R-value Thickness (inch) Width (inch) Length (inch) Pieces Per Pack Packs Per Pallet Pieces / pallet Square Feet Per Pack Square Feet Per Pallet
328171 4 1 24 48 7 26 56 1456
205480 4 1 48 72 40 960
328173 5 1.25 24 48 5 30 40 1200
168586 5 1.25 48 72 32 768
308720 Comfortboard 110 6 1.5 24 48 5 24 40 960
307525 Comfortboard 110 6 1.5 48 72 30 720
328175 Comfortboard 110 8 2 24 48 4 24 32 768
168590 8 2 48 72 20 480
169061 10 2.5 24 48 3 20 24 480
308717 10 2.5 48 72 16 384
328177 12 3 24 48 3 20 24 480
168588 12 3 48 72 15 360
328487 14 3.5 24 48 3 18 24 432
307527 16 4 24 48 2 24 16 384
307555 20 5 24 48 2 20 320

We can't find any results that match your search

Load More
Back

Tools, Guides & Downloads

 

 

print pdf
icon
COMFORTBOARD 110 for Continuous Insulation - Brochure
COMFORTBOARD 110 for Continuous Insulation - Brochure

pdf
ComfortBoard110 - Aislante revestimiento de alto rendimiento termico
ComfortBoard110 - Aislante revestimiento de alto rendimiento termico

pdf
icon
COMFORTBOARD 110 - 072113 GUIDESPEC - English - Canada
COMFORTBOARD 110 - 072113 GUIDESPEC - English - Canada

Specifications

pdf
icon
COMFORTBOARD 110 - 072113 GUIDESPEC - English - United States
COMFORTBOARD 110 - 072113 GUIDESPEC - English - United States

Specifications

pdf
icon
Stone Wool Insulation for Below Grade Applications
Stone Wool Insulation for Below Grade Applications

ROCKWOOL stone wool insulation can be used for below grade applications to minimize heat transfer between a building and the ground, reducing energy consumption and enhancing occupant comfort. ROCKWOOL Comfortboard® products are ideal solutions for below grade applications due to their ability to handle compressive loads, resist water absorption, and maintain dimensional stability to ensure long-term performance.

pdf
icon
QAI Code Evaluation Report 2022
QAI Code Evaluation Report 2022

This report verifies that the listed ROCKWOOL products comply with the stated code requirements, while clearly indicating to code officials how to identify the products, the approved applications of the products and installation requirements.

pdf
icon
Dimensional Stability of Rigid Board Insulation Products
Dimensional Stability of Rigid Board Insulation Products

Rigid foam insulation products (EPS, XPS and ISO) are dimensionally affected with changes in temperature. Stone wool insulation, on the other hand, has negligible expansion and contraction when compared to these other insulation types.

pdf
icon
Below Grade with Stone Wool FAQ
Below Grade with Stone Wool FAQ

Download this FAQ document for a collection of common questions and answers related to product installation, testing and performance when working with stone wool in below grade foundation wall and slab-on-grade assemblies

pdf
icon
Guidelines for Cutting Stone Wool Insulation
Guidelines for Cutting Stone Wool Insulation

This document provides essential steps and best practices for cutting ROCKWOOL stone wool insulation. It includes information on preparation, recommended tools, safety measures, and cutting techniques to ensure accurate and clean cuts. These guidelines help maintain the material's performance and integrity, making it suitable for both professionals and DIY users.

pdf
COMFORTBOARD Mid-Rise Wood Construction - Technical Guide
COMFORTBOARD Mid-Rise Wood Construction - Technical Guide

pdf
icon
Cladding Attachment Solutions For Exterior Insulated Commercial Walls
Cladding Attachment Solutions For Exterior Insulated Commercial Walls

This guide will help with evaluating an appropriate cladding attachment strategy by providing details on the implications these decisions have on effective thermal performance, installation methods, sequencing and system costs. An overview of nine different cladding support systems utilizing ROCKWOOL insulation products is included.

pdf
icon
Board Insulation Attachment Guide
Board Insulation Attachment Guide

Get recommendations and view diagrams for attaching ROCKWOOL semirigid and rigid board insulation products for most common applications, including cladding attachment systems or plain board installation.

pdf
icon
Comfortboard® 110 Continuous Insulation - Data Sheet
Comfortboard® 110 Continuous Insulation - Data Sheet

Rigid non-structural exterior sheathing stone wool insulation boards used as continuous insulation to hep create high-performance wall assemblies to improve the energy efficiency and fire resilience of buildings.

pdf
icon
Safe Use Instruction Sheet
Safe Use Instruction Sheet

This document is provided by ROCKWOOL to communicate recommended safe handling and use instructions.

pdf
Back

Questions? Contact Us

If you have technical questions about products or need support for your project, our technical experts are here to help you.

Contact Us