Sandwich Wall Sound panels OEM Insulation

ROCKWOOL Conrock®

Conrock® is a board insulation that is designed specifically for application in a sandwich wall panel system where excellent thermal and fire resistance properties are required. Conrock has excellent sound dampening properties, is dimensionally stable, vapor permeable and will not encourage the growth of mold.

Conrock® can help achieve 1, 2 and 3 hour fire ratings in sandwich wall panel assemblies. 

Back
Back

Specification & sizes

Compliance ASTM C612 - ASTM E84 (UL723) - CAN/ULC S102 - CAN4 S114
ASTM C612 Mineral Fiber Block and Board Thermal Insulation Type IVA, Complies
ASTM E84 (UL723) Surface Burning Characteristics - Smoke Developed = 5 Flame Spread = 0
CAN/ULC S102 Surface Burning Characteristics - Flame Spread = 0 Smoke Developed = 10
CAN4 S114 Test for Non-Combustibility - Non-Combustible
Density
8.5 lb/ft3 (136 kg/m3)
Dimensional stability ASTM C356
ASTM C356  Linear Shrinkage 0.19%
Dimensions
For details on sizing, please contact our customer service representatives
Thermal resistance ASTM C518 (C177)
ASTM C518 (C177)  R-value / inch @ 75°F - 4.0 hr.ft2.F/Btu
  RSI value / 25.4 mm @ 24°C - 0.71 m2K/W
Reaction to moisture ASTM C1104
ASTM C1104

Moisture Sorption 0.05%

Compressive strength ASTM C165
ASTM C165 at 10% 4" Board: 6.64 psi (45.8 kPa)
Corrosion Resistance ASTM C665 - ASTM C795
ASTM C665 Corrosiveness Passed
ASTM C795 Conforms to Stainless Steel Stress Corrosion Specification as per Test
ASTM C795 Methods C871 and C692: U.S. Nuclear Regulatory
ASTM C795 Commission, Reg. Guide #1.36: U.S. Military Specifications
ASTM C795 MIL-I-24244 (all versions including B and C)
Back
ASTM C612 Mineral Fiber Block and Board Thermal Insulation Type IVA, Complies
ASTM E84 (UL723) Surface Burning Characteristics - Smoke Developed = 5 Flame Spread = 0
CAN/ULC S102 Surface Burning Characteristics - Flame Spread = 0 Smoke Developed = 10
CAN4 S114 Test for Non-Combustibility - Non-Combustible
Back
8.5 lb/ft3 (136 kg/m3)
Back
ASTM C356  Linear Shrinkage 0.19%
Back
For details on sizing, please contact our customer service representatives
Back
ASTM C518 (C177)  R-value / inch @ 75°F - 4.0 hr.ft2.F/Btu
  RSI value / 25.4 mm @ 24°C - 0.71 m2K/W
Back
ASTM C1104

Moisture Sorption 0.05%

Back
ASTM C165 at 10% 4" Board: 6.64 psi (45.8 kPa)
Back
ASTM C665 Corrosiveness Passed
ASTM C795 Conforms to Stainless Steel Stress Corrosion Specification as per Test
ASTM C795 Methods C871 and C692: U.S. Nuclear Regulatory
ASTM C795 Commission, Reg. Guide #1.36: U.S. Military Specifications
ASTM C795 MIL-I-24244 (all versions including B and C)
Back

Tools, Guides & Downloads

 

 

print pdf
icon
CONROCK & CONROCK 60 for SWP & OEM Fabrication - Brochure
CONROCK & CONROCK 60 for SWP & OEM Fabrication - Brochure

pdf
icon
CONROCK Sandwich Wall Panel Insulation - Tech data
CONROCK Sandwich Wall Panel Insulation - Tech data

pdf
icon
Safe Use Instruction Sheet
Safe Use Instruction Sheet

This document is provided by ROCKWOOL to communicate recommended safe handling and use instructions.

pdf
System.Threading.Tasks.Task`1[Microsoft.AspNetCore.Html.IHtmlContent]